Educational Disclaimer: This article is for informational purposes only and does not constitute legal or regulatory advice. The Construction Products Regulation and its harmonised standards are amended periodically, and CE marking obligations depend on the specific product and intended use. Always verify current requirements against official CPR and CEN sources and consult a qualified regulatory specialist or notified body before making compliance decisions. Regulation version and effective dates are stated where known and were current at time of writing (September 2026).

A structural glazing sealant that fails a curtain wall joint years after installation is not just a maintenance problem — it is a building envelope failure that can mean water ingress, panel detachment risk, and a liability trail that leads straight back to whoever supplied and specified the sealant. In the European Union, that risk sits squarely inside the Construction Products Regulation, Regulation (EU) No 305/2011 (CPR), which has applied in full since 1 July 2013 and governs CE marking structural sealants CPR compliance for every joint sealant covered by a harmonised standard. Selling a sealant into a harmonised category without a valid CE mark and Declaration of Performance is not a paperwork oversight the market tolerates — it can trigger product withdrawal, blocked public procurement, and building-control rejection on live projects. This guide explains what the CPR requires of a structural sealant manufacturer, how EN ISO 11600 classification feeds into the Declaration of Performance, and how to build a compliance pathway that survives a notified body audit or a market surveillance check. It reflects the CPR and its supporting harmonised standards as they stand in 2026; always confirm the current status of the relevant standard before relying on any specific classification route.

What the Construction Products Regulation Is and Why It Exists

The CPR replaced the earlier Construction Products Directive 89/106/EEC to close a gap that had frustrated the EU single market for decades: national testing and approval regimes for construction products meant a sealant certified in one member state often had to be re-tested and re-approved to be sold in another. The Regulation applies directly across every member state without national transposition, and it fixes a single mechanism — the Declaration of Performance backed by CE marking — through which a manufacturer states, once, how a product performs against the essential characteristics that matter for its intended construction use.

The CPR does not set minimum performance thresholds itself. Instead, it obliges the manufacturer to test the product against the essential characteristics defined in the relevant harmonised technical specification and to declare the result honestly, whatever that result is. It is then left to national building regulations, procurement specifications, and the specifying architect or engineer to decide what level of each characteristic a given project requires. For a structural sealant, this means the regulation exists to guarantee that the movement class, adhesion performance, and durability printed on the Declaration of Performance are the actual, independently verified figures — not marketing claims — so a specifier anywhere in the EU can compare products on a common, trustworthy basis.

Scope: Who the CPR Applies To and Which Sealants Are Covered

The CPR applies to any construction product placed on the EU market where a harmonised technical specification exists and covers that product's intended use. For sealants, the key harmonised standard is EN 15651, published in parts that separately address facade sealants, glazing sealants, sanitary sealants, and sealants for pedestrian walkways. A sealant manufacturer, importer, or authorised representative bringing a covered product into the EU carries the CE marking obligation regardless of where the product is physically manufactured, and the obligation attaches to the specific intended use claimed, not to the chemistry of the sealant in the abstract.

EN 15651 Part Covered Use Typical Sealant Chemistry
Part 1 Facade elements Silicone, polyurethane, MS polymer
Part 2 Glazing Neutral-cure silicone, structural glazing silicone
Part 3 Sanitary joints Fungicide-modified silicone
Part 4 Pedestrian walkways Polyurethane, MS polymer, polysulfide

A sealant sold exclusively for a use outside these four categories, or one for which no harmonised standard yet exists, does not carry a mandatory CE marking obligation under the CPR, though many manufacturers still commission the same testing voluntarily because architects and public procurement specifications increasingly expect a Declaration of Performance as a baseline qualification document. Structural glazing sealants deserve particular attention: where a sealant is used as the primary structural attachment between glass and frame rather than purely as a weather seal, the essential characteristics that must be declared, and in some cases the applicable AVCP system, differ from a purely weatherproofing joint. Our guide to silicone sealant types and grades sets out the chemistry distinctions between weatherproofing and structural glazing formulations that feed into this scope question.

Key Requirements: Declaration of Performance and CE Marking

Once a sealant falls inside the scope of EN 15651, three obligations follow in sequence: the essential characteristics relevant to the intended use must be tested and classified, a Declaration of Performance must be drawn up stating those results, and the CE mark must be affixed with reference to that Declaration. Skipping any one of the three — testing without declaring, declaring without marking, or marking without current testing — breaks compliance even if the underlying product performs well.

Essential Characteristics and EN ISO 11600 Classification

EN 15651 references EN ISO 11600 for the movement-capability and modulus classification that forms the technical core of the Declaration of Performance. Under EN ISO 11600, a sealant is classified by a movement class figure — such as 12.5, 20, or 25 — expressing the maximum percentage of joint width the sealant can accommodate through repeated extension and compression without adhesive or cohesive failure, combined with a category letter set (F or G for the general class, and LM or HM for low or high modulus) describing the force the cured sealant exerts on the substrate at that movement. A structural glazing joint exposed to significant thermal cycling needs a materially different classification than a static sanitary joint, so the declared class must match the actual joint design movement calculated for the building detail in question.

Assessment and Verification of Constancy of Performance (AVCP)

The CPR assigns each essential characteristic an AVCP system that fixes how conformity is assessed and by whom. Most characteristics for sealants under EN 15651 fall under AVCP System 3, meaning an accredited, notified testing laboratory carries out initial type testing to determine the product's performance, while the manufacturer itself operates factory production control and self-declares performance without ongoing notified body surveillance of production. Some structural and fire-related characteristics can carry a stricter system requiring notified body certification of the factory production control system itself, so the applicable AVCP system must be confirmed characteristic by characteristic rather than assumed for the product as a whole.

CE marking structural sealants regulatory pathway diagram — CPR harmonised standard testing and Declaration of Performance route | Global Formulation
The CPR compliance sequence for a structural sealant: harmonised standard identification, EN ISO 11600 classification testing, Declaration of Performance drafting, and CE mark affixing — each step dependent on the one before it.

Testing and Documentation Requirements

The evidence base behind a compliant CE mark has to satisfy two different audiences at once: a market surveillance authority checking the Declaration of Performance is genuine, and a specifying engineer relying on the declared movement class to design a real joint. Because of this dual purpose, sealant manufacturers must hold both the formal conformity documents and the underlying test data, not just a signed declaration.

  • Initial type testing report — the accredited laboratory's test report determining movement capability class, elastic recovery, tensile properties, and adhesion/cohesion performance under EN ISO 11600 and the relevant EN 15651 part.
  • Declaration of Performance (DoP) — the formal document identifying the product, its AVCP system, the harmonised standard reference, and the declared level for every essential characteristic, issued before the CE mark is affixed.
  • Factory production control (FPC) records — documented evidence that ongoing production is monitored against the same parameters verified during initial type testing, including raw material checks and batch testing logs.
  • CE marking label content — the CE symbol itself accompanied by the notified body number where applicable, the last two digits of the year the marking was first affixed, manufacturer identification, and a reference to the DoP.
  • Safety Data Sheet — reflecting the CLP classification of the cured and uncured sealant, maintained consistently with any hazard-related essential characteristics declared.
  • Retest triggers documentation — a record of any formulation, raw material, or manufacturing process change that could affect a declared characteristic, and confirmation of whether it required new initial type testing.

A Declaration of Performance is only as reliable as the initial type test it rests on, so it expires in practice the moment a formulation changes materially. Treat every reformulation as a trigger to review, not an administrative afterthought.

Step-by-Step Compliance Pathway to CE Marking

Reaching a compliant CE mark for a structural sealant follows a defined sequence, and the order matters: testing must exist before the Declaration of Performance is written, and the Declaration must exist before the CE mark is affixed. The steps below map that sequence for a sealant manufacturer supplying the EU market.

  1. Identify the applicable EN 15651 part and confirm scope. Match the sealant's intended use — facade, glazing, sanitary, or pedestrian walkway — to the correct part of the harmonised standard, and confirm the product genuinely falls within its scope.
  2. Commission initial type testing with an accredited laboratory. Submit representative production samples for EN ISO 11600 movement classification and the other essential characteristics required by the relevant EN 15651 part.
  3. Determine the applicable AVCP system for each characteristic. Confirm whether notified body involvement is required beyond initial type testing, based on the essential characteristics being declared and the standard's assigned system.
  4. Draft the Declaration of Performance. Compile the tested results into the DoP format required by CPR Annex III, stating declared levels honestly, including any characteristics for which "No Performance Determined" is the accurate answer.
  5. Establish factory production control. Implement and document the raw material checks, in-process controls, and batch release testing needed to demonstrate that ongoing production matches the tested product type.
  6. Affix the CE mark and publish the DoP. Apply the CE mark to the product, packaging, or accompanying documents per CPR Article 9, referencing the DoP, and make the DoP available in the language required by each member state of sale.
  7. Monitor for retest triggers. Track formulation, raw material, and process changes on a controlled basis, and repeat initial type testing whenever a change could plausibly affect a declared essential characteristic.
Key Compliance Principle The obligation most sealant manufacturers underestimate is that a Declaration of Performance tied to an old formulation becomes false the moment the recipe changes materially — even if the CE mark stays on the label. Reformulating a sealant without re-testing and re-issuing the DoP is one of the most common ways manufacturers unknowingly fall out of compliance.
CE marking structural sealants compliance requirements infographic — EN ISO 11600 classification and essential characteristics | Global Formulation
The essential characteristics a structural sealant Declaration of Performance must address, mapped against their AVCP assessment route and the EN ISO 11600 classification each depends on.

Realistic Timeline and Cost Expectations

CE marking a new structural sealant is a multi-month technical programme, not a form-filling exercise, because the classification testing itself takes time to run correctly and cannot be meaningfully compressed. Understanding the real cost drivers helps a manufacturer budget the programme accurately rather than being surprised by the testing timeline midway through a product launch.

Initial type testing for EN ISO 11600 movement classification typically requires curing and conditioning cycles measured in weeks before cyclic movement testing can even begin, followed by the test sequence itself and laboratory reporting time — a realistic total of two to four months for a first-time submission, longer if any result requires reformulation and retesting. The main cost categories are accredited laboratory fees for initial type testing, internal technical time to prepare samples and interpret results, DoP drafting and multilingual translation for each market of sale, and — where a stricter AVCP system applies — notified body fees for factory production control certification and its ongoing surveillance visits.

Reformulation after a failed or marginal classification result is the timeline risk that catches manufacturers off guard: a sealant that narrowly misses its target movement class or elastic recovery threshold must be reformulated and the full initial type testing cycle repeated, effectively resetting the clock. Building in a testing buffer before a firm launch date, and validating a formulation against the target classification internally before committing to accredited laboratory testing, meaningfully de-risks the programme.

Common Mistakes Manufacturers Make — and How to Avoid Them

Most CPR non-compliance in the sealant sector is not deliberate — it stems from treating CE marking as a one-time certificate rather than a live obligation tied to the exact tested formulation and use. The patterns below recur across market surveillance findings and specification disputes, and each is preventable with a disciplined process.

  • Reformulating without retesting. Changing a raw material, catalyst level, or filler loading can shift movement capability or adhesion performance enough to invalidate the existing Declaration of Performance, even though the CE mark stays unchanged on the packaging.
  • Confusing weatherproofing classification with structural glazing requirements. A sealant classified and declared for a facade weather-seal joint is not automatically qualified for a structural glazing attachment role, which can carry different essential characteristics and AVCP treatment.
  • Issuing a DoP before testing is complete. Drafting the Declaration of Performance ahead of receiving final, accredited test results and then not correcting it if results differ is a direct breach of Article 4's requirement that declared performance reflect actual, verified test outcomes.
  • Applying the CE mark without a corresponding DoP reference. The CE mark is only meaningful attached to a specific Declaration of Performance; using it without one, or with a DoP that has lapsed due to formulation change, is treated as non-compliant marking.
  • Overlooking member state language requirements for the DoP. Distributing a product into a new member state without providing the Declaration of Performance in that state's required language can block procurement acceptance even when the underlying technical compliance is sound.
  • Assuming a foreign national approval substitutes for CE marking. A sealant approved under a non-EU national scheme, or under an old pre-CPR national mark, still needs full CPR conformity to be lawfully placed on the EU market.

For background on the chemistry decisions that shape which classification a sealant can realistically achieve, the Global Formulation guide to MS polymer hybrid sealants covers movement and modulus trade-offs across chemistries, while the adhesives and sealants formulation guide sets out the broader additive and cure-system landscape. Official CPR guidance is maintained by the European Commission and EUR-Lex at Regulation (EU) No 305/2011, and the harmonised classification standard is published by ISO at iso.org/standard/69818.

Frequently Asked Questions

Does every sealant need CE marking under the Construction Products Regulation?
No. CE marking under the CPR is only mandatory where a harmonised technical specification exists for that product and covers the intended use, and the manufacturer places the product on the EU market for a construction purpose. EN 15651, in its various parts, is the harmonised standard covering sealants for facades, glazing, sanitary joints, and pedestrian walkways, so sealants sold into those applications generally require CE marking. A sealant marketed purely for non-construction uses, or one that falls outside the scope of a harmonised standard, may not carry a mandatory CE marking obligation, though many manufacturers still test and declare performance voluntarily to support specification by architects and engineers.
What is the difference between EN 15651 and EN ISO 11600 for sealants?
EN 15651 is the harmonised product standard under the CPR that triggers the CE marking obligation and defines the Declaration of Performance requirements for sealants used in facade, glazing, sanitary, and pedestrian-walkway joints. EN ISO 11600 is the classification standard that sealants are tested against to determine movement capability class and elastic or plastic recovery behaviour, expressed as designations such as F 25LM or G 20HM. In practice the two work together: EN 15651 sets out which essential characteristics must be declared and how conformity is assessed, while EN ISO 11600 supplies the movement-class and modulus classification that becomes part of the declared performance.
Do I need a notified body to CE mark a structural sealant?
It depends on the Assessment and Verification of Constancy of Performance (AVCP) system assigned to the relevant essential characteristic in the harmonised standard. Most sealant characteristics under EN 15651 fall under AVCP System 3, where an accredited third-party laboratory determines the product type through initial type testing, but the manufacturer self-declares performance and manages factory production control without ongoing notified body surveillance. Some structural glazing and fire-related characteristics can carry stricter AVCP systems requiring notified body certification of factory production control. The applicable system is fixed by the harmonised standard itself, not chosen by the manufacturer, so it must be confirmed for each essential characteristic being declared.
What does the Declaration of Performance need to include for a sealant?
A Declaration of Performance must identify the product type, its intended use, the manufacturer, the AVCP system applied, the harmonised standard reference, and — critically — the declared performance for every essential characteristic listed in that standard, using the classification levels the product actually achieved in testing. For a facade sealant this typically includes movement capability class, elastic recovery, tensile properties, and durability performance, each stated as tested rather than as a marketing claim. The DoP must be made available in the language required by the member state of sale and must be issued before the CE mark is affixed; a CE mark without a corresponding DoP is not compliant.
Can I sell a CE marked sealant across all EU member states without further testing?
In principle, yes — the CPR was designed precisely so that a valid CE mark and Declaration of Performance allow free movement of the product across all EU and EEA member states without additional national testing or marking. In practice, some member states apply national provisions on aspects not harmonised by the standard, such as specific fire classification requirements or regional durability expectations, and public procurement specifications may reference additional national test methods. It remains good practice to check the destination member state's construction product regulator or trade association guidance before large-scale distribution of a newly CE marked product.
What happens if a structural sealant is placed on the EU market without a valid CE mark?
Placing a product covered by a harmonised standard on the EU market without CE marking, or with a CE mark unsupported by a valid Declaration of Performance, is a breach of the CPR and can trigger market surveillance action including product withdrawal, sales suspension, and financial penalties set by national law. For structural and safety-critical applications such as curtain wall glazing, the consequences extend beyond regulatory enforcement: a building using non-compliant sealant may fail building control sign-off, and the installer or specifier can face liability if a joint failure is later traced to an undeclared or misdeclared product. Distributors and importers also carry obligations to verify that a DoP exists before making the product available.
How is movement capability class determined for a facade or glazing sealant?
Movement capability class is determined by cyclic movement testing under EN ISO 11600, where a cured sealant joint of standard geometry is repeatedly extended and compressed by a defined percentage of its original width while adhesion and cohesion are monitored for cracking, tearing, or bond failure. The class — such as 12.5, 20, or 25 — states the percentage total movement the joint can accommodate without failure, and the accompanying letter and number code (for example LM for low modulus or HM for high modulus) describes the force the sealant exerts on the substrate at that movement. A structural glazing joint with high thermal movement demands a higher movement class than a static sanitary joint, so the class must be matched to the actual joint design movement calculated for the building detail, not selected from a generic product data sheet alone.

Need Regulatory Guidance for Your Sealant Product Launch?

Our team provides end-to-end regulatory strategy — from CPR scope assessment and EN ISO 11600 classification planning to Declaration of Performance drafting and notified body coordination.

Get a Free Consultation
AK

Absar Khan

Founder & Lead Consultant, Global Formulation

Absar Khan is a senior industrial consultant with cross-disciplinary expertise spanning pharmaceutical manufacturing, cosmetics and personal care, home and institutional care chemicals, aerosols, lubricants, and advanced process engineering. His work integrates formulation chemistry, GMP facility design, validation science, quality systems, regulatory compliance, and large-scale manufacturing optimisation.

Connect on LinkedIn →

Message on WhatsApp