ASHRAE energy audits:
Level 1, 2 and 3.

Findings costed, ranked and ready for a decision.

We carry out energy audits of industrial and commercial facilities at the three levels set out in ASHRAE Standard 211: a walk-through, an energy survey and analysis, and a detailed analysis of capital projects. You receive a costed, ranked list of measures, not just a list of problems.

Energy Audit Scope

The building and utility systems that use energy, assessed together.

Energy
Audit
Utility bills & tariff analysis
01
Heating, ventilation & cooling
02
Chilled water & cooling towers
03
Boilers, steam & condensate
04
Compressed air & vacuum
05
Pumps, fans & motors
06
07
Lighting & controls
08
Building envelope & insulation
09
Heat recovery options
10
Metering & sub-metering
11
Savings measures & costing
12
Indoor environmental quality
Audit Mapping

ASHRAE Audit Levels & Deliverables

What each level covers, what you receive, and when it is the right choice.

Service Area
What We Deliver
Where It Applies
Engineering Detail

Level 1: walk-through analysis

Audit levels
Energy-use baseline from utility bills
Walk-through findings
List of no-cost and low-cost measures
A first look at a facility, or a check on whether a deeper audit is justified.
⚙️

Scope & Configuration

A review of energy bills and tariffs and a short site walk-through to spot obvious waste and decide where to look next.

Design Basis

Utility bills and tariffs, equipment lists and operating hours.

📐

Method & Approach

Normalise energy use, compare it with similar facilities, walk the site with the operating team, and note the quick savings and the capital projects worth studying.

Risk & Quality Controls

Savings are indicative at this level and are not a sound basis for an investment decision on their own.

Level 2: energy survey and analysis

Audit levels
Energy use broken down by system
Costed savings measures with payback
Peak demand analysis
The usual choice for a facility that wants a costed list of measures to act on.
⚙️

Scope & Configuration

A detailed survey of the systems that use energy, a breakdown of consumption by end use, and engineering calculations and cost estimates for each measure.

Design Basis

Metered or interval data where available, equipment data and operating profiles, and the local energy tariffs.

📐

Method & Approach

Survey and measure the main systems, build the end-use breakdown, calculate the saving for each measure, and estimate its cost and payback.

Risk & Quality Controls

Assumptions are stated for every calculation, and measures that interact, such as lighting and cooling load, are not double counted.

Level 3: detailed analysis of capital projects

Audit levels
Measured data for the target systems
Energy model or detailed calculation
Life-cycle cost analysis
Large capital projects, such as replacing chiller or boiler plant, where the decision needs firm numbers.
⚙️

Scope & Configuration

In-depth analysis of the larger measures found at Level 2, supported by measurement and a more rigorous financial analysis.

Design Basis

Short-term logging of the equipment concerned, detailed operating profiles and supplier quotations.

📐

Method & Approach

Measure the target systems, model annual energy use before and after the change, and compare the options on life-cycle cost.

Risk & Quality Controls

The analysis is documented well enough for a lender, insurer or board to review it.

HVAC and chilled water

Systems reviewed
Plant and distribution assessment
Control strategy review
Savings measures
Production halls, laboratories, cleanrooms, warehouses and offices.
⚙️

Scope & Configuration

Cooling, heating, ventilation and chilled-water systems, their controls and the way they are run.

Design Basis

Equipment data, schedules, temperature and ventilation requirements, and operating hours.

📐

Method & Approach

Compare how the plant is run with how it was designed, check set points, schedules and part-load behaviour, and size the measures that follow.

Risk & Quality Controls

Ventilation, pressure and cleanliness requirements of each space are kept whatever savings are proposed.

Steam, boilers and process heat

Systems reviewed
Boiler and steam-system assessment
Insulation and steam-trap survey
Heat-recovery options
Plants with steam, hot-water or thermal-fluid systems.
⚙️

Scope & Configuration

Generation, distribution and use of heat, including condensate return, insulation and waste-heat recovery.

Design Basis

Fuel use, the steam demand profile and boiler data.

📐

Method & Approach

Balance heat supply against demand, find the losses in generation and distribution, and test heat-recovery options.

Risk & Quality Controls

Safety-critical equipment is not changed for an energy measure without a hazard review.

Compressed air, pumps and motors

Systems reviewed
Compressor and leak assessment
Pump and fan load review
Drive and motor measures
Process plants and workshops.
⚙️

Scope & Configuration

The electric drives and utility systems behind much of a plant’s electricity use.

Design Basis

Motor and compressor data, load profiles and operating hours.

📐

Method & Approach

Log power and flow on the main machines, compare them with what the process needs, and size options such as variable-speed drives and control changes.

Risk & Quality Controls

Process requirements for flow, pressure and air quality are confirmed before a measure is proposed.

Lighting, envelope and metering

Systems reviewed
Lighting survey and controls options
Envelope and insulation findings
Sub-metering plan
Buildings of every type.
⚙️

Scope & Configuration

Lighting and its controls, the building fabric, and the meters needed to track results.

Design Basis

Light-level requirements, building drawings and the tariff structure.

📐

Method & Approach

Survey fittings and controls, check envelope losses, and specify the sub-metering needed to verify savings afterwards.

Risk & Quality Controls

Light levels are kept to the standard for the task being done.

ASHRAE Standard 211 reporting

Standards & reporting
Audit report structured to the agreed level
Savings, cost and payback tables
Prioritised action plan
Owners who want a report that follows a recognised structure and can be compared with later audits.
⚙️

Scope & Configuration

Reporting that follows the minimum scope, analysis and reporting content that ASHRAE Standard 211 sets for each audit level.

Design Basis

ASHRAE Standard 211, applied at the level agreed in the scope of work.

📐

Method & Approach

Agree the level and the facility boundary at the start, then structure the findings, calculations and recommendations to match.

Risk & Quality Controls

The level, boundary and assumptions are stated in the report so that results can be compared year on year.

ISO 50002 and EN 16247 reporting

Standards & reporting
Audit scope and boundary statement
Energy use by system or process
Measures register
Facilities that need an audit of process energy use, or that work to ISO 50001.
⚙️

Scope & Configuration

Audits reported to ISO 50002 or the EN 16247 series where the contract or the regulator calls for them.

Design Basis

The audit standard named in the contract and the energy-audit rules of the country concerned.

📐

Method & Approach

Collect the data once, keep one measures register, and report it in the framework the client requires.

Risk & Quality Controls

Country-specific audit requirements are confirmed with the client at the start.

Measurement and verification

Standards & reporting
Verification plan
Meter and logger schedule
Savings report after implementation
Projects where savings must be proven, for example to a lender or an energy-performance contract.
⚙️

Scope & Configuration

Checking that implemented measures deliver the savings that were predicted.

Design Basis

A baseline period and a reporting method agreed at the start, such as ASHRAE Guideline 14 or IPMVP.

📐

Method & Approach

Fix the baseline, meter the affected systems, adjust for weather and production, and compare results with the prediction.

Risk & Quality Controls

The method and its uncertainty are agreed before the measures are installed.

How an energy audit runs

Energy Audits

Know Where the Energy Goes

An audit is only as good as its data and its scope, so we fix both before anyone walks the site.

Scroll to follow the workflow
Insulated HVAC ducts, red fire protection pipework, cable trays and lighting under the roof of an industrial building
01 Scope

Scope & Level Selection

Agree the facility boundary, the audit level, the standard to report against and the data we need from you.

Speak With Our Engineers
Stainless steel vessels and blue pipework on multi-level platforms in a process plant
02 Baseline

Data Collection & Baseline

Gather utility bills, tariffs, equipment lists and operating hours, and set the energy baseline.

Speak With Our Engineers
Insulated steam vessel with valves, pipework and a relief valve venting steam in a utility plant room
03 Survey

Site Survey

Walk the site with the operating team, record equipment condition and controls, and measure the main loads.

Speak With Our Engineers
MEP services in an industrial building: insulated HVAC ducts, red sprinkler pipework and cable trays
04 Analysis

Analysis & Measures

Break energy use down by system, calculate the saving for each measure, and estimate cost and payback.

Speak With Our Engineers
Insulated HVAC ducts, red fire protection pipework, cable trays and lighting under the roof of an industrial building
05 Report

Report & Action Plan

Issue the report in the structure the audit level requires, with measures ranked and the assumptions stated.

Speak With Our Engineers
Skid-mounted pump and valve station with stainless steel pipework in an industrial hall
06 Verify

Implementation & Verification

Support implementation and check, with metering, that the predicted savings are delivered.

Speak With Our Engineers
Let's Collaborate

Want to know where your facility wastes energy?

Tell us about the site, its utility bills and the level of audit you need, and we will outline the scope and the data required.

Discuss an Energy Audit
Knowledge Base

Utilities & Energy Knowledge Base

Cooling, steam, condensate and cleanroom guides from our technical team.

FAQ

Frequently asked questions

Straight answers to the questions we hear most often.

What is an ASHRAE energy audit?

ASHRAE Standard 211, Commercial Building Energy Audits, defines three audit levels and sets the minimum scope, analysis and reporting for each. An audit carried out and reported to one of those levels is commonly called an ASHRAE audit. The levels run from a walk-through to a detailed analysis of capital projects.

What is the difference between a Level 1, Level 2 and Level 3 audit?

Level 1 is a walk-through that reviews utility bills and spots obvious waste. Level 2 is an energy survey and analysis: it breaks energy use down by system and gives costed measures with payback. Level 3 is a detailed analysis of capital-intensive modifications, with measurement, modelling and a life-cycle cost study. The boundaries between levels are not sharp, so the scope of work should say what is included.

Which audit level do I need?

Choose Level 1 to find out whether a deeper audit is justified, Level 2 when you want a costed list of measures to act on, and Level 3 before committing to a large capital project such as replacing chiller or boiler plant. Many facilities start at Level 2 because it gives a usable list of measures. We help you choose the level when we agree the scope.

Does an ASHRAE audit cover production processes?

ASHRAE Standard 211 is a standard for building energy audits. Where the energy used by production processes is part of the question, audits are often reported to ISO 50002 or to EN 16247-3, which covers processes. We agree the framework with you at the start and use the same data and the same measures register for either.

What do you need from us to start?

Utility bills and tariffs, equipment lists or drawings, operating hours, and access to the people who run the plant. The deeper the audit level, the more detail is needed, up to metering or short-term logging of specific equipment at Level 3.

Will an audit disturb production?

Level 1 and most Level 2 work are walk-throughs and non-intrusive measurement. Level 3 may need data loggers on specific equipment, which we plan with your operating team so that production and safety-critical systems are not affected.

How do ASHRAE Standard 100 and an energy audit relate?

ASHRAE Standard 100, the performance standard for existing buildings, sets energy and emissions targets. In its 2024 edition, buildings that miss their targets must carry out an energy audit and a decarbonization assessment. We structure audits to the Standard 211 levels, and the level that a particular regulation or programme requires should be confirmed against that regulation. Whether Standard 100 applies to you depends on the building type and on whether your jurisdiction has adopted it.